A field kit for the determination of chloride ion content in concrete, fresh cement, masonry, most other construction materials, and water.
Applications
Service life prediction
Corrosion analysis
Features & Benefits
Fast - Results within minutes at the site.
Economical - Low cost per sample compared to laboratory testing.
Accurate - Results are comparable to laboratory testing.
Covers wide range from 0.002% to 2% chloride by weight
Internal Memory to store readings for later upload to a PC via USB.
Digital display for direct reading of percentage of chloride by weight.
Conforms to AASHTO-T- 260.
Menu in English and Spanish.
The Chlorimeter produces results on-site, within minutes that are accurate and comparable to expensive laboratory tests. It measures the electrochemical reaction of a weighted sample placed in an extraction liquid. It automatically shows a temperature compensated reading of percent of chlorides on its digital display. A wide range - from 0.002 to 2% chloride by weight - is covered.
Technical
The determination of the chloride ion concentration in concrete is essential in assessing the need for maintenance on, for example, bridge decks and parking structures. The test can also be used to ensure that materials used in new construction are free from potentially harmful chloride ion levels.
With this method, the concentration of acid soluble chlorides is measured. In most cases, this is equivalent to total chloride concentration.
A sample of powder is obtained by drilling and careful quartering. Then an accuray weighed 3 gr. (0.1 oz) sample is dissolved in 20 ml (0.67 fl. oz.) of extraction liquid which consists of a precise, measured concentration of acid. For sampling wet concrete a 3 gr. (0.1 oz.) sample of mortar (i.e. without coarse aggregate) is used. Typically for concrete, samples that are to be analyzed for chloride are obtained at various depths, thereby supplying the engineer with a chloride ion profile.
The chloride ions react with the acid of the extraction liquid in an electrochemical reaction. An electrode, with integral temperature sensor, is inserted into the liquid and the electrochemical reaction measured.
A uniquely designed instrument converts the voltage generated by the chloride concentration and sensor into a reading for the user. The instrument automatically applies the temperature correction and it shows the chloride concentration on a LCD display percentage by weight. The unit uses 4 'AA' batteries for power. The Chlorimeter can also store test results and upload them to PC via USB.
Once the sample is obtained, test results can be determined and read in less than five minutes. These initial values give a valuable indicator of the current chloride concentration values. Accurate results are typically obtained after the sample has been in the extraction liquid for 24 hours.
To avoid contamination, the electrode should be thoroughly washed with de-ionized water after each test.
Replacement packs, containing twelve bottles of extraction liquid, each for one time use, are available. Five calibration liquids each with known concentrations are supplied with each pack. Bulk packs of one hundred extraction liquids are also available for larger testing jobs.
Thecalibration liquids are used to establish the calibration curve, and to check that the system is functioning correctly. Calibration is not required for each use. The calibration liquids are colored to avoid confusion between them and with the extraction liquid.
All equipment necessary to complete the chloride test is supplied in a standard size carrying case.
Chloride combination electrode with externally mounted temperature sensor, cable, and connectors.
C-CL 3020
Battery powered, high impedance, electronic meter, with temperature compensation circuits and microprocessor for direct conversion to percentage of chloride. Uses four 'AA" size batteries.
C-CL 2012
Optional pack of 12 jars each with 20 ml (0.67 fl. oz.) of extraction liquid and 5 jars of colored calibration liquid.
C-CL 1030
Bottle of electrode wetting agent.
C-CL 2096
Optional bulk pack of 100 jars extraction liquid and 20 jars of colored calibration liquid.
以上是美國NDT James C-CL-3000 Chlorimeter混凝土氯離子含量測定儀的詳細信息,如果您對美國NDT James C-CL-3000 Chlorimeter混凝土氯離子含量測定儀價格、廠家、品牌、型號、圖片、規(guī)范、規(guī)格、原理有疑問,或需要詳細報價單、宣傳冊、中英文產品說明書,請點擊我公司
美國NDT James相關產品介紹:
美國NDT James T-HT-1000 Humiditest混凝土鉆孔濕度測試儀
美國NDT James T-C-10 T-C-20 Cementometer微波水泥含水率測試儀
美國NDT James T-S-30 Aquaprobe微波土壤含水率測試儀
美國NDT James T-M-170 Aquameter混凝土含水率測試儀
美國NDT James T-T-90 Trident插針式微波骨料含水率測試儀
美國NDT James I-CB-6000 Carbo Detect混凝土碳化深度酸堿指示劑
美國NDT James I-AS-3000 ASR-Detect混凝土堿骨料反應測試儀
美國NDT James A-AB-1200 A-AV-1300 A-AA-1100 Air Meters混凝土含氣量測試儀
美國NDT JAMES Z-WP-1000 Windsor Probe混凝土強度槍擊檢測儀
美國NDT JAMES W-P-2000 Windsor Pin混凝土強度檢測儀
美國NDT JAMES R-HR-8000 Mini R-Meter鋼筋定位儀
美國NDT JAMES P-C-7300 Bond Test MK III粘結強度測試儀
美國NDT JAMES P-C-728 P-C-729 Anchor錨栓測試儀
美國NDT JAMES M-M-3056 Maturity Meter混凝土成熟度測試儀
美國NDT JAMES Datascan MK II鋼筋混凝****達
美國NDT James C-P-6000 C-P-6050 Porosiscope混凝土滲氣滲水性測試儀